LogoLogo
ProductsDevelopersAPI ReferenceContact Us
OmniSIM
OmniSIM
  • OmniSIM
  • Get started
    • eSIM activation and testing quick start guide
    • Prepaid plans quick start guide
    • SIM states
  • OmniSIM Reach
    • OmniSIM Reach - Centralized Multi-IMSI
  • OmniSIM eSIM
    • OmniSIM Product Datasheet
    • What is a SIM, eSIM, iSIM?
    • OmniSIM 1.3 What is New?
    • Identify OmniSIM Versions
    • OmniSIM Power Saving
  • How to..
    • OmnSIM APN Settings
    • OmniSIM Multi-IMSI Top Tips
    • OmniSIM Troubleshooting Tips
    • Local Profile Management Guide
    • OmniSIM - GSMA Test Profile (TS.48)
  • Device guides
    • Maximum transmission units (MTUs) in devices
    • Quectel BG95 BG96 BG77 extended configuration settings
    • Quectel BG95 BG96 BG77 APN settings
    • Cradlepoint E300EU APN Settings
    • How Devices Manage eSIM Profile Management & Power Management
  • Advisories
    • Retiring OmniSIM Reach 1.1 (SKU: 14239, 14240, 14639, 16474) - 6th August 2024
  • eSIM switch
    • eSIM switch process
    • eSIM switch - monitor and troubleshooting
On this page
  • Overview
  • Enable the Test Profile
  • Disable the Test Profile

Was this helpful?

  1. How to..

OmniSIM - GSMA Test Profile (TS.48)

PreviousLocal Profile Management GuideNextMaximum transmission units (MTUs) in devices

Last updated 1 year ago

Was this helpful?

This documentation applies to the following products:

  • OmniSIM

For all other products, please review their respective documentation

Overview

OmniSIM comes with a GSMA Test Profile (TS.48 - Generic eUICC Test Profile for Device Testing).

The Test profile is disabled by default and is not referenced in CPro or the SM-DP (RSP).

OmniSIM Test profile is aligned with TS.48 v4.x

The Test Profile can be Enabled and Disabled by sending an APDU to the SIM with a CSIM AT Command.

Please note that although KORE has a Test Profile on OmniSIM it is not supported and we assume the user has knowledge of how to use the TS.48 Test Profile with their device.

Enable the Test Profile

The following AT command can be used to send the APDU to instruct the card to switch to the TS.48 Test profile.

Switch to TS.48 Profile
AT+CSIM=16,"80C2000003E40102"
Response
+CSIM: 4,"6103"
OK

The device will lose connectivity and possibly reset. The Test Profile will be enabled

Disable the Test Profile

The following AT command can be used to send the APDU to instruct the card to switch from to the last enabled KORE profile.

Switch back to KORE
AT+CSIM=16,"80C2000003E40103"
Response
+CSIM: 4,"6103"
OK

The device will roll-back to the KORE profile and reconnect to the cellular network.